Buyer pays for return postage. Take a look at our Returning an item help page for more details. You're covered by the eBay Money Back Guarantee if you receive an item that is not as described in the listing. The buyer is responsible for return postage costs. Return policy details. Returns accepted. Most purchases from business sellers are protected by the Consumer Contract Regulations which give you the right to cancel the purchase within 14 days after the day you receive the item.
Find out more about your rights as a buyer and exceptions. Back to home page Return to top. More to explore:. Ended: 12 Jan, GMT. Similar sponsored items. Seller assumes all responsibility for this listing. Item specifics. Seller Notes:. Battery Operated. Monitor Parameters:. Protocol Welch Allyn. Solaris Xpress movi-star Visit Store: Solaris Xpress. Business seller information. Contact details. Movi Star.
Return policy. It snaps easily into the Transport Pro unit displaying real time waveforms throughout the transfer process. On return the Tram module transfers patient data back to the monitoring system. Units shipped do not include Tram Multi-parameter module. Units include a 1-year warranty.
The bedside can be configured with either the standard display or the optional flat panel display. The basic Solar Information Monitor consists of the Solar processing unit, a compatible touch screen display and one or more acquisition devices.
The processing unit is the heart of the system. User controls are provided by the touch screen display; however, a keyboard and mouse may also be used.
Up to two additional displays may be attached directly to the Solar Information Monitor to display layout configurations separate from the Primary Display. The display is a dual trace, monochrome display that is easy to read.
The unit can be configured for adult or neonate performance. There are additional parameters available as options. The unit has an optional strip chart recorder that can be included. It has a large monochrome display and a built-in recorder. Function keys around the face of the display make for ease of use and configuration.
Configured waveforms and alpha numeric are displayed in an easy to read format. The device can be used on battery or AC power, which makes it an excellent choice for transport monitor. The Escort 2 can be configured for neonate or adult patients.
This device is shipped with power cord, new battery, patient cable, spo2 sensor, nibp cuff, and hose operators manual and a 1-year warranty. The Escort Prism SE is an extremely compact and lightweight 11 pounds portable monitor. These units are scalable with up to 11 vital signs and 5 waveforms being displayed on the large color LCD display.
The unique combination of features set new standards for flexibility, performance and value. This unit is the perfect balance of bedside and transport capabilities that make it an ideal solution for a broad range of patient care applications. Available options include ETCO2. The Escort M10 is an extremely compact and lightweight 11 pounds portable monitor.
The BSM A monitor provides exceptional performance in a lightweight case. The unit is battery or line operated. It has a built in color LCD with touch screen. This unit is sold with all necessary accessories for immediate operation. The patient parameters are the same. The major difference between units is that the BSM A uses a larger Both are color and both are touchscreen. All necessary accessories are shipped with the unit as well as operators manual and a 1-year warranty.
The Life Scope P has various configurations as a bedside monitor. It also has two multi-parameter sockets for monitoring invasive blood pressure, temperature, respiration thermistor method , CO, CO2, and FIO2. The unit also has a built-in recorder for manually or automatically recording waveforms, numeric data, trend graphs, and vital sign lists.
The large color display has a wide-viewing angle and all monitoring parameters are automatically identified. For portability this unit can operate on battery as well as AC power. It is extremely flexible and portable. It functions very well in a variety of capacities with in the healthcare system. It is battery or line-operated and can be configured for either Adult of Neonate modes of operation.
Also included is an operators manual and a 1-year warranty. The Philips M2 Monitor is designed to be a portable lightweight monitor. It has an easy to read color display that has a wide viewing angle. The MMS module selected determines the parameters to be monitored and displayed. This quality monitor is sold with new batteries and power cord. An operators manual and a 1-year warranty are included.
The Philips MP 2 is a versatile, lightweight, and extremely portable device. It was designed for those times when your nts need to be transported and monitored from area to area within the healthcare setting. The Philips MP 2 monitor has a clear, easy to read 3.
The built-in touch-screen makes navigating between parameters and screens extremely simple. If there is any doubt about the integrity of the protective earth ground of the receptacle for the power adapter, do not plug in the power adapter; operate the monitor only on battery power.
Contact your biomedical engineering department for assistance in identifying the proper power receptacle and making appropriate power connections. WARNING Avoid electrosurgery burns at monitoring sites by ensuring proper connection of the electrosurgery return circuit so that the return paths cannot be made through monitoring electrodes and probes. WARNING To ensure patient safety, the conductive parts of the ECG electrodes including associated connectors and other patient-applied parts should not contact other conductive parts, including earth ground, at any time.
WARNING Do not operate this product in the presence of flammable anesthetics or other flammable substance in combination with air, oxygenenriched environments, or nitrous oxide; explosion can result. WARNING Within certain governmental jurisdictions, all interconnected accessory equipment must be labeled by an approved testing laboratory. After interconnection with accessory equipment, risk leakage current and grounding requirements must be maintained. The operator should not attempt to open the monitor case or perform any maintenance on the monitor except for procedures explicitly described in this manual that can be performed by operators such as inspection and cleaning.
Visit www. The use of any other accessories can result in inaccurate patient data, can damage the equipment, and can void your product warranty. Within certain governmental jurisdictions, all interconnected accessory equipment must be labeled by an approved testing laboratory.
WARNING As with all medical equipment, carefully route the patient cabling to reduce the possibility of patient entanglement or strangulation. WARNING A product that has been dropped or severely abused should be checked by qualified service personnel to verify proper operation and acceptable risk leakage current values. WARNING If the monitor detects an unrecoverable problem, an error message window appears containing an error number and a short message.
Report such errors to Welch Allyn. Also make sure the blood pressure cuff is properly placed according to.
Prolonged impairment of circulation or improper cuff placement can cause contusions. Operation of the monitor outside the range of specified values is not recommended and may cause inaccurate results. WARNING Electronic equipment that emits very strong electromagnetic or radio frequency signals can cause electrical interference with monitor operation, including causing the monitor to turn off power. Avoid operating this monitor near such equipment. For guidance about electromagnetic emissions and the recommended separation distance between the monitor and such equipment, refer to the specifications section of this manual.
Caution Federal U. The Propaq Encore must be serviced only by a Welch Allyn service technician while under warranty. Propaq Encore Service Manual XX is available from Welch Allyn to assist the biomedical engineer during post-warranty period service. The following symbols may appear on the Propaq Encore monitor or accessories or documentation.
Caution In this manual, indicates conditions that could damage equipment or other property. This device has been tested and certified by the Canadian Standards Association International to comply with applicable U. The Propaq Encore documentation set consists of documents for the clinician, the biomedical technician, and the department head or purchaser of accessories for the Propaq Encore monitors. This Propaq Encore Reference Guide contains important safety and operating information for the clinician.
Propaq Encore Service Manual XX contains information on how to properly maintain the Propaq Encore through routine calibration, inspection, and maintenance. This Reference Guide provides descriptions and operating information for the Propaq Encore models EL, EL, and EL, including all available options at the time of this manual's printing. This Reference Guide was written for the clinician. The Propaq Encore has been designed as a quality monitor; however, inherent limitations require that good clinical judgment always prevails.
Before using the Propaq Encore on a patient, be sure you understand the Safety Summary at the front of this book. It provides important information about safely using the Propaq Encore. The Propaq Encore monitor is intended to be used by skilled clinicians for multiparameter vital signs monitoring of neonatal, pediatric, and adult patients in health care facility bedside applications; as well as for intraand interfacility transport.
Capnography CO 2 available only with SpO 2 :. The Propaq Encore Expansion Module attaches to the monitor and houses additional capabilities. The Propaq Encore CO 2 options allow carbon-dioxide monitoring.
The mainstream CO 2 option and sidestream CO 2 option allow CO 2 monitoring directly in the breathing circuit of a ventilator. The sidestream CO 2 option also allows CO 2 monitoring of non-intubated patients through a cannula.
These options require the Pulse Oximetry SpO 2 option. This option allows communication between the Propaq Encore and the Acuity Central Monitoring System by means of an ethernet network system installed in your facility.
The Acuity System operator can view the patient data and control most of the bedside Propaq functions. The Propaq Encore connects to the Acuity System through an Acuity network cable that plugs into the Propaq right side panel. This option allows telecommunication between a Propaq Encore and the Acuity System by means of external modems. This option is configured with the Propaq-to-Acuity option. For more information refer to Modem-Propaq Reference Guide. This option replaces the standard Propaq Encore left side panel.
Defib Sync Connector Contact Welch Allyn technical support for information for specifications, see page This switch turns the monitor on and off. The switch is recessed to prevent accidentally turning off the monitor, which would result in losing patient data.
The input fuse, which protects the Propaq Encore against power surges, is a 3-Ampere fuse, externally replaceable by qualified service personnel.
This receptacle accepts the Welch Allyn ac power adapter, which must be used for ac mains operation and battery charging. The Propaq Encore is also designed to operate with other volt, dc-only power sources, such as a vehicle battery system.
This green light turns on when a power source ac power adapter or external dc source is connected and the battery is charging. Although the monitor may be turned off, battery charging continues when an external power source is connected. This connector allows either direct connection to an Acuity System, or connection to an external modem for telecommunication to an Acuity System. When you first turn on the monitor, the power-up screen displays information about the Propaq Encore and the monitor runs diagnostic tests to ensure proper functioning.
A few seconds later, the top two lines of the screen are replaced with text indicating the current patient mode adult, pediatric, or neonatal. If the Propaq Encore has been used for a previous patient, switch the monitor off, then on again. The monitor will turn on in the powerup patient mode with the associated settings.
Note Verify that the powerup tone is produced. If the monitor has SpO 2 , verify two tones are produced to make sure that both speakers are working. If the patient mode is not correct, change it. The patient mode determines default alarm limits, maximum cuff inflation pressure, and internal algorithm settings.
Verify the battery voltage is sufficient for monitoring. If it is less than 7. This can occur if the battery is drained or after new software has been installed. If this occurs, the monitor provides a special sequence of display windows to help you regain use of your monitor as quickly as possible.
Do the following:. Connect an ac power adapter to recharge the battery if the battery is drained. Press any button below the equipment alert screen to acknowledge the alert. The monitor will display the Mode Setup window shown on page Press these buttons to select one of the Factory patient modes for use:.
Turn off the monitor, then turn it on again so the settings will take effect. The monitor is ready for use. If you want to store some customized patient mode program settings, refer to page If you follow these steps and the equipment alert reappears at powerup, the monitor may need to be serviced and the battery replaced. Contact a qualified service person. The left side panels differ depending on the Propaq Encore model.
The Propaq Encore left side panel includes one invasive-pressure connector, and the Propaq Encore includes two invasivepressure connectors. On Propaqs with the Hewlett-Packard connector option, all models have only one temperature connector, the YSI connector. The display shows waveforms, vital sign numeric values, Propaq Encore status, and alarm information in different windows.
Different vital sign numeric values such as heart rate and blood pressures have upper and lower range limits. If the Propaq Encore detects a vital sign value outside of the Propaq's measurable range, the monitor displays — — —. Above beats per minute, it may display incorrectly low heart rates, due to intermittent picking of R-waves.
Note Due to differences in software versions and standards required by different countries, the displays shown in this reference guide may be slightly different than the display on your Propaq Encore.
The screenspace is reallocated when vital signs are added or removed. By changing the size of the numeric windows below the heart rate, the Propaq Encore provides the best possible view of all numerics for vitals signs being monitored. You can select up to three waveforms to be shown on the Propaq. When only one waveform is selected, a trend window automatically appears below the waveform.
While changing Propaq Encore settings, a status window may appear below the waveform. The four buttons at the sides of the screen are reserved for the most commonly used functions. NIBP The five labels above the associated. The five buttons below the screen, and their associated labels located on the screen, provide access to the menus.
Menus for some patient vital signs are displayed only if that option is included in your Propaq. It will always be CO 2 if CO 2 is active. MCO 2 BR. If you change the patient mode, the CO 2 alarm limits in the new mode might vary slightly from the originally-programmed CO 2 limits for the new mode.
Check the CO 2 alarm limits. This allows you to set custom patient modes and powerup defaults as described on page
0コメント